Tracing Helium Test Rig Leaks in Food Packaging with Acoustic Imaging

Oct 28, 2026
Cover 4 Cover 4

Many production lines in the food industry use helium leak test rigs to check packaging seal integrity. Helium mass spectrometry equipment can accurately determine whether a package is leaking, but the complete test system contains numerous components that must remain leak-tight, including regulators, manifolds, hoses, quick couplings, valves, gas injection assemblies, fixture seals and chamber connections.

 

A leak on the positive-pressure side of the rig can cause several production problems. Helium consumption may rise unexpectedly, background readings may take too long to stabilise, purge and stabilisation cycles may become longer, and repeated tests may produce inconsistent results. Operators may keep retesting packaging samples without finding the underlying problem, resulting in unnecessary downtime, helium loss and reduced productivity. In many cases, the fault lies in the upstream helium test rig rather than the packaging being tested.

 

Established inspection methods include helium mass spectrometry, pressure-decay testing and bubble testing. A helium mass spectrometer can measure leak rates accurately, while pressure testing can assess the tightness of an isolated section. However, locating a particular leaking connection or seal within a complex assembled rig often requires maintenance personnel to follow the gas circuit point by point, isolate sections and apply leak detection fluid. Finding the leak can take longer than repairing it.

 

As a complementary tool within the existing inspection process, an acoustic camera helps narrow the search for suspected leaks. When the helium rig is operating at the specified test pressure differential, gas escaping through a gap can generate an acoustic signal. The camera uses a microphone array to overlay acoustic hotspots on a visible-light image. Without touching each connection, maintenance personnel can survey a group of positive-pressure components within one view, including regulator outlets, manifolds, hose connections, quick couplings, valves, injection needles and fixture seals.

 

How Acoustic Imaging Narrows the Search

When there is sufficient pressure difference, gas escaping through a small opening generates high-frequency airborne sound. An acoustic camera uses its microphone array to determine the direction of the sound and overlays a hotspot on the visible-light image.

 

From a suitable position, technicians can survey several exposed components within the same view without approaching each connection individually. If a stable hotspot repeatedly appears around a manifold, hose connection, valve or fixture seal, subsequent inspection with helium-specific equipment or another approved method can focus on a much smaller area.

 

Laboratories and production environments often have vacuum pumps, fans, motors and pneumatic equipment operating at the same time. Adjusting the frequency range and observing a suspected source from another angle can reduce the influence of unrelated noise and reflections, making it easier to distinguish locations that deserve closer inspection.

 

The visual overlay also makes findings easier to communicate. Other technicians can see which connection produced a suspected signal, where the camera was positioned and how the equipment was operating during the scan.

 

Where to Scan First

The first scan is best directed towards areas that offer a clear view, are on the positive-pressure side and contain several potential leak points close together. These include regulator outlets and manifold connections, hose and rigid-pipe fittings, quick couplings and gas-circuit changeover points, control valves, injection ports and needles, fixture sealing surfaces and chamber joints.

 

A broad scan across these groups of components can quickly show whether acoustic activity is concentrated at a particular location. This helps reduce trial and error and directs the team towards the next area to investigate: the packaging itself, the test fixture or the upstream gas supply infrastructure.

Image 4 Image 4

 

From Hotspot Location to Maintenance Records

The practical process is straightforward. First, keep the test rig in its normal testing or maintenance state. Begin with a broad view from a distance, then move closer to the suspected area. If the hotspot remains associated with the same component area when viewed from another angle, mark the location and record the operating conditions.

 

Following the site’s compressed-gas procedures, isolate the relevant section of the circuit and release the pressure before inspecting and repairing its connections, hoses, valves and seals. Once the repair is complete, confirm the result using an appropriate helium-specific detection method and carry out the rig’s routine suitability checks before resuming packaging tests.

 

Adding voice or text notes when saving an image creates a practical handover record. Notes can identify the rig, the relevant fixture, the suspected connection, the test conditions and any action already taken. Where several production lines use the same type of test rig, capturing images from the same position during subsequent inspections can help build a continuous maintenance history. Teams can then review previous work without searching through scattered records to establish which component was repaired.

 

How HIKMICRO Acoustic Cameras Fit into the Existing Process

HIKMICRO AI Series acoustic cameras visualise detectable sound generated by pressurised gas leaks. The range includes the AI56, AI56L and AI76, with low-noise MEMS microphone arrays, adjustable frequency filtering and sound-source locations displayed over a visible-light image.

 

In a helium testing area, these capabilities address one of the most time-consuming maintenance tasks: deciding which connection to inspect first. Technicians can narrow a group of potential leak points to a particular valve, connection or seal area before using helium detection equipment for targeted confirmation.

 

The cameras can save images with voice or text annotations, while HIKMICRO Analyzer Acoustic supports subsequent review and reporting. This makes it easier to hand over suspected locations to other technicians, attach inspection evidence to work orders and compare the same area after repair.

 

AI Series acoustic cameras locate detectable sound from escaping gas, they do not identify whether that gas is helium. Suspected locations should therefore be confirmed using the appropriate helium detection method, and the test rig should be validated after repair before packaging tests resume.

 

Finding the Next Inspection Point Faster

When helium consumption rises or test background readings remain unstable, an acoustic camera can help the team examine the equipment surrounding the packaging test before beginning another lengthy connection-by-connection search. It makes suspected leak locations visible, shows colleagues where to investigate next and provides a record that can accompany the maintenance work.

 

The investigation becomes more direct: scan the pressurised test rig, focus on acoustic hotspots, confirm the leak source, complete the repair and validate the test system. Established helium detection methods continue to provide the packaging test results, while acoustic imaging helps maintenance personnel reach the connections that need attention more quickly.

Hikmicrotech.com would like to use analytics cookies and other similar tracking technologies ("Cookies") to help us improve our website. The Cookies collect information in a way that does not directly identify anyone. For more information about the Cookies we use, see our cookies policy here.