HIKMICRO is extending acoustic imaging beyond industrial gas leak detection into food processing, automotive manufacturing and repair, heating, ventilation, air conditioning and refrigeration (HVAC‑R), rail transport and helium test rig maintenance. Its AI Series cameras help maintenance teams locate sound sources and target follow-up inspections.
A pressure drop, reduced performance or an unusual noise may signal a problem without revealing its source. AI Series cameras use microphone arrays to capture sound and display source locations as coloured hotspots on a visible-light image. Technicians can scan a broad area, identify locations of interest and use appropriate specialist methods to confirm suspected faults.
Compressed air leaks in food and beverage plants can increase compressor load, waste energy and affect supply stability. Machinery noise and elevated pipework can make them difficult to locate.
In a beverage plant survey reported by HIKMICRO, technicians used an AI Series camera to inspect the compressed air system. Its low-noise MEMS microphone array captured acoustic signals, while the team adjusted the frequency band to reduce interference from compressor room noise. The acoustic overlay revealed five suspected leak locations around tee connections and a valve, giving technicians specific points for confirmation and repair.
Refrigerant leaks and unusual noises can be difficult to trace among closely arranged or partly concealed components in the engine bay, underbody or around trim panels.
Under suitable operating or test conditions, the acoustic image helps technicians narrow the search for suspected refrigerant leaks and identify areas for further noise, vibration and harshness (NVH) investigation.
For sounds that occur at a particular engine speed or during component operation, technicians can save images and add voice or text notes to record the conditions for later inspection and workshop handovers.
In manufacturing, acoustic surveys help teams prioritise leak checks across the compressed air systems serving welding, painting and assembly, supporting routine maintenance and energy management.
For HVAC-R professionals, acoustic imaging offers a practical way to screen distributed components and complex pipe networks. Plant rooms, rooftop installations and cold stores may contain numerous valve assemblies, flanges and pipe connections, making individual checks time-consuming.
Where a sufficient pressure differential exists and escaping gas produces detectable sound, technicians can first identify suspected source areas, then use an appropriate refrigerant detector, bubble solution or another approved method for confirmation. Concentrating close inspection within a smaller area helps teams address leaks that affect system energy efficiency and reliability.
HIKMICRO is exploring acoustic imaging for both observations of moving trains and leak detection on stationary vehicles. In a German trackside test, the AI56 visualised differences in acoustic activity between wheel positions as a train passed, without contacting the vehicle. The results provided location references for further investigation and demonstrated the potential of acoustic imaging for condition screening.
In depots, acoustic cameras can help locate compressed air leaks in the pipes, valves and air reservoirs serving braking, air suspension and pneumatic door systems on stationary vehicles. Repeated observations under comparable conditions, linked to subsequent inspection findings, can also help maintenance teams build a baseline for comparison over time.
The maintenance of helium test rigs used in food packaging illustrates a more specialised application. These systems contain numerous potential leak points, including regulators, manifolds, hoses, quick couplings and fixture seals.
For leaks on the positive-pressure side that produce detectable sound, an acoustic camera can survey several components before technicians concentrate on suspected connections or seal areas. This reduces the need to begin with detailed checks at every individual point. Acoustic imaging provides a location reference for the escaping gas; suspected leaks still require confirmation using an appropriate helium detection method, helping the team complete repairs and restore stable test operation.
Across these applications, maintenance teams also need to retain findings for handovers and follow-up checks. AI Series cameras support image capture with voice and text annotations, allowing users to record equipment details, suspected locations and inspection conditions. HIKMICRO Analyzer Acoustic enables subsequent image review, analysis and report preparation, helping field observations become part of the maintenance record.
Food production, automotive manufacturing and repair, HVAC-R maintenance, railway inspection and helium test rig troubleshooting place different demands on inspection teams. By developing approaches suited to each setting, HIKMICRO is extending the role of acoustic imaging beyond conventional industrial gas leak surveys and building a broader range of specialist inspection solutions. The company will continue to explore further applications around practical user needs, helping professionals identify areas of concern, focus their investigations and improve maintenance and operational efficiency.
For more information, visit www.hikmicrotech.com.