Tepelne odolné guľové kamery HIKMICRO

Thermographic-Heat-Resistant-Bullet-Camera
Tepelne odolná strela
Práca pri vysokej okolitej teplote Prostredie do 200°C s prídavným vzduchovým alebo kvapalinovým chladiacim systémom
technické údaje
Product Model
Check the product for comparison
Thermographic Integration
Temperature Metadata
Thermographic Data Encoding
Thermographic Data Upload
Raw Data Upload
Video and Image
Main Stream
Video Compression
Color Palettes
Network
Protocols
API
Simultaneous Live View
User/Host level
Security
Client
General
Menu Language
Power Supply
Working Temperature/Humidity
Protection Level
Dimensions
Weight
Measurement and Analysis
Object Temperature Range
Temperature Accuracy
Measurement Presets
Point
Line
Area
Color Alarm (Isotherm)
Thermal Module
Image Sensor
Resolution
Pixel Pitch
Spectral Range
NETD
Focal Length
Focus Mode
IFOV
Aperture
Field of View
Min. Focusing Distance
Digital Zoom
High-temperature Resistance
Cooling Liquid
Cooling Air
Interface
Alarm Input
Alarm Output
Communication Interface
Analog Output
HM-TD2H67H1-15/Q
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/H.265/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
MODBUS, ISAPI, Network SDK, Open Network Video Interface (Profile S, Profile G)
Up to 20 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 4.8 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
0°C to 800°C (32°F to 1472°F), 600°C to 1800°C (1112°F to 3272°F)
Object temperature 100°C to 1800°C (212°F to 3272°F),±2% for ambient temperature 18°C to 25°C (64.4°F to 77°F) and ±3% for ambient temperature 25°C to 50°C (64.4°F to 77°F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
10 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
640 x 512
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
15 mm
Athermalized
1.13 mrad
F1.5
41.5° × 33.3° (H × V)
0.5 m
1×, 2×, 4×, 8×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M/1000 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H67H1-25/Q
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/H.265/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
MODBUS, ISAPI, Network SDK, Open Network Video Interface (Profile S, Profile G)
Up to 20 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 4.8 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
0°C to 1800 °C (32 °F to 3272 °F)
Object temperature 100°C to 1800°C (212°F to 3272°F),±2% for ambient temperature 18°C to 25°C (64.4°F to 77°F) and ±3% for ambient temperature 25°C to 50°C (64.4°F to 77°F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
10 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
640 x 512
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
25 mm
Semi-auto & Manual
0.68 mrad
F1.5
24.8° × 19.9° (H × V)
0.5 m
1×, 2×, 4×, 8×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M/1000 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H67T-6/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
640 x 512
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
6.3 mm
Athermalized
2.70 mrad
F1.0
88.5° × 73.2° (H × V)
0.6 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H37T-4/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
Φ138 mm × 352 mm (Φ5.43" x 13.88")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
384 x 288
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
4.5 mm
Athermalized
3.78 mrad
F1.0
90° × 65.2° (H × V)
0.3 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H37T-10/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
384 x 288
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
9.7 mm
Athermalized
1.75 mrad
F1.0
37.5° × 28.5° (H × V)
1.5 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H37T-7/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
384 x 288
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
6.5 mm
Athermalized
2.62 mrad
F1.0
60° × 44.1° (H × V)
0.6 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
View More
View Less
Clear All
Compare
Compare Products(2/6)
View Detail
Compare
Clear All
Compare

Hikmicrotech.comby sme chceli používať analytické súbory cookie a iné podobné technológie sledovania („cookies“), aby nám pomohli zlepšiť našu webovú stránku. Súbory cookie zhromažďujú informácie spôsobom, ktorý nikoho priamo neidentifikuje. Viac informácií o súboroch cookie, ktoré používame, nájdete v našomcookies policytu.

súhlasiť
Odmietnuť
Spravovať súbory cookie
Online Service
Contact Sales
Become a Dealer
Technical Support
Where to Buy
close