Heat Resistant Bullet Camera
Working at high ambient temperature Environment up to 200°C with additional air or liquid cooling system

 

*Note: The above information is for reference only, the produce in kind prevails.

Specifications
Product Model
Thermal Module
Image Sensor
Pixel Pitch
NETD
Focus Mode
IFOV
Field of View
Min. Focusing Distance
Aperture
Digital Zoom
Spectral Range
Focal Length
Resolution
Measurement and Analysis
Object Temperature Range
Measurement Presets
Point
Line
Area
Color Alarm (Isotherm)
Temperature Accuracy
General
Protection Level
Weight
Menu Language
Power Supply
Working Temperature/Humidity
Dimensions
Thermographic Integration
Temperature Metadata
Thermographic Data Encoding
Thermographic Data Upload
Raw Data Upload
Video and Image
Main Stream
Video Compression
Color Palettes
Network
Protocols
API
Simultaneous Live View
User/Host level
Security
Client
Interface
Communication Interface
Alarm Input
Alarm Output
Analog Output
High-temperature Resistance
Cooling Liquid
Cooling Air
HM-TD2H67H1-15/Q
HM-TD2H67H1-15/Q
Vanadium Oxide Uncooled Focal Plane Arrays
17 μm
≤ 35 mK (@25° C,F# = 1.0)
Athermalized
1.13 mrad
41.5° × 33.3° (H × V)
0.5 m
F1.5
1×, 2×, 4×, 8×
8 μm to 14 μm
15 mm
640 x 512
0°C to 800°C (32°F to 1472°F), 600°C to 1800°C (1112°F to 3272°F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
10 User Presets
Above/Between/Below
Object temperature 100°C to 1800°C (212°F to 3272°F),±2% for ambient temperature 18°C to 25°C (64.4°F to 77°F) and ±3% for ambient temperature 25°C to 50°C (64.4°F to 77°F)
IP67
Approx. 6520 g (14.37 lb)
English
10-30 VDC, Max. 4.8 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/H.265/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
MODBUS, ISAPI, Network SDK, Open Network Video Interface (Profile S, Profile G)
Up to 20 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
1, RJ45 10 M/100 M/1000 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, CVBS output
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
HM-TD2H67H1-25/Q
HM-TD2H67H1-25/Q
Vanadium Oxide Uncooled Focal Plane Arrays
17 μm
≤ 35 mK (@25° C,F# = 1.0)
Semi-auto & Manual
0.68 mrad
24.8° × 19.9° (H × V)
0.5 m
F1.5
1×, 2×, 4×, 8×
8 μm to 14 μm
25 mm
640 x 512
0°C to 1800 °C (32 °F to 3272 °F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
10 User Presets
Above/Between/Below
Object temperature 100°C to 1800°C (212°F to 3272°F),±2% for ambient temperature 18°C to 25°C (64.4°F to 77°F) and ±3% for ambient temperature 25°C to 50°C (64.4°F to 77°F)
IP67
Approx. 6520 g (14.37 lb)
English
10-30 VDC, Max. 4.8 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/H.265/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
MODBUS, ISAPI, Network SDK, Open Network Video Interface (Profile S, Profile G)
Up to 20 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
1, RJ45 10 M/100 M/1000 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, CVBS output
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
HM-TD2H67T-6/X
HM-TD2H67T-6/X
Vanadium Oxide Uncooled Focal Plane Arrays
17 μm
≤ 35 mK (@25° C,F# = 1.0)
Athermalized
2.70 mrad
88.5° × 73.2° (H × V)
0.6 m
F1.0
2×, 4×
8 μm to 14 μm
6.3 mm
640 x 512
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Max (± 2 °C, ± 2%)
IP67
Approx. 6520 g (14.37 lb)
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, CVBS output
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
HM-TD2H37T-4/X
HM-TD2H37T-4/X
Vanadium Oxide Uncooled Focal Plane Arrays
17 μm
≤ 35 mK (@25° C,F# = 1.0)
Athermalized
3.78 mrad
90° × 65.2° (H × V)
0.3 m
F1.0
2×, 4×
8 μm to 14 μm
4.5 mm
384 x 288
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Max (± 2 °C, ± 2%)
IP67
Approx. 6520 g (14.37 lb)
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
Φ138 mm × 352 mm (Φ5.43" x 13.88")
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, CVBS output
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
HM-TD2H37T-10/X
HM-TD2H37T-10/X
Vanadium Oxide Uncooled Focal Plane Arrays
17 μm
≤ 35 mK (@25° C,F# = 1.0)
Athermalized
1.75 mrad
37.5° × 28.5° (H × V)
1.5 m
F1.0
2×, 4×
8 μm to 14 μm
9.7 mm
384 x 288
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Max (± 2 °C, ± 2%)
IP67
Approx. 6520 g (14.37 lb)
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, CVBS output
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
HM-TD2H37T-7/X
HM-TD2H37T-7/X
Vanadium Oxide Uncooled Focal Plane Arrays
17 μm
≤ 35 mK (@25° C,F# = 1.0)
Athermalized
2.62 mrad
60° × 44.1° (H × V)
0.6 m
F1.0
2×, 4×
8 μm to 14 μm
6.5 mm
384 x 288
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Max (± 2 °C, ± 2%)
IP67
Approx. 6520 g (14.37 lb)
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, CVBS output
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
View More
View Less
Firmware
HM_Firmware_TD2H67_X_5.5.70_230908.zip
Nov 7, 2023
42A63A3444D195D440200BB5E92E6845
HM_Firmware_TD2H37_X_5.5.70_230908.zip
Nov 7, 2023
8CE567FB384A6E74248D8BB07EB11684

Hikmicrotech.com would like to use analytics cookies and other similar tracking technologies ("Cookies") to help us improve our website. The Cookies collect information in a way that does not directly identify anyone. For more information about the Cookies we use, see our cookies policy here.

Accept
Reject
Manage Cookies
Online Service
Contact Sales
Become a Dealer
Technical Support
Where to Buy
close