Cámaras bullet resistentes al calor de HIKMICRO

Thermographic-Heat-Resistant-Bullet-Camera
Cámaras Bullet resistente al calor
Funciona en alta temperatura de ambiente hasta 200 °C con un sistema adicional de refrigeración líquida o por aire

 

*Aviso: La información anterior es solo de referencia; prevalece la imagen real del producto.

Especificaciones
Modelo de producto
Check the product for comparison
Thermographic Integration
Temperature Metadata
Thermographic Data Encoding
Thermographic Data Upload
Raw Data Upload
Video and Image
Main Stream
Video Compression
Color Palettes
Network
Protocols
API
Simultaneous Live View
User/Host level
Security
Client
General
Menu Language
Power Supply
Working Temperature/Humidity
Protection Level
Dimensions
Weight
Measurement and Analysis
Object Temperature Range
Temperature Accuracy
Measurement Presets
Point
Line
Area
Color Alarm (Isotherm)
Thermal Module
Image Sensor
Resolution
Pixel Pitch
Spectral Range
NETD
Focal Length
Focus Mode
IFOV
Aperture
Field of View
Min. Focusing Distance
Digital Zoom
High-temperature Resistance
Cooling Liquid
Cooling Air
Interface
Alarm Input
Alarm Output
Communication Interface
Analog Output
HM-TD2H67H1-15/Q
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/H.265/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
MODBUS, ISAPI, Network SDK, Open Network Video Interface (Profile S, Profile G)
Up to 20 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 4.8 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
0°C to 800°C (32°F to 1472°F), 600°C to 1800°C (1112°F to 3272°F)
Object temperature 100°C to 1800°C (212°F to 3272°F),±2% for ambient temperature 18°C to 25°C (64.4°F to 77°F) and ±3% for ambient temperature 25°C to 50°C (64.4°F to 77°F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
10 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
640 x 512
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
15 mm
Athermalized
1.13 mrad
F1.5
41.5° × 33.3° (H × V)
0.5 m
1×, 2×, 4×, 8×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M/1000 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H67H1-25/Q
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/H.265/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
MODBUS, ISAPI, Network SDK, Open Network Video Interface (Profile S, Profile G)
Up to 20 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 4.8 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
0°C to 1800 °C (32 °F to 3272 °F)
Object temperature 100°C to 1800°C (212°F to 3272°F),±2% for ambient temperature 18°C to 25°C (64.4°F to 77°F) and ±3% for ambient temperature 25°C to 50°C (64.4°F to 77°F)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
10 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
640 x 512
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
25 mm
Semi-auto & Manual
0.68 mrad
F1.5
24.8° × 19.9° (H × V)
0.5 m
1×, 2×, 4×, 8×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M/1000 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H67T-6/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 640 × 512 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 640 × 512) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (640 × 512)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
640 x 512
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
6.3 mm
Athermalized
2.70 mrad
F1.0
88.5° × 73.2° (H × V)
0.6 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H37T-4/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
Φ138 mm × 352 mm (Φ5.43" x 13.88")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
384 x 288
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
4.5 mm
Athermalized
3.78 mrad
F1.0
90° × 65.2° (H × V)
0.3 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H37T-10/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
384 x 288
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
9.7 mm
Athermalized
1.75 mrad
F1.0
37.5° × 28.5° (H × V)
1.5 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
HM-TD2H37T-7/X
Continuous output data of preset thermographic rules and measured temperature
4 fps, 32-bit 384 × 288 per frame
Real-time full-screen thermographic data matrix (16-bit or 32-bit 384 × 288) via RTSP,
ISAPI, and SDK
Real-time full-screen YUV data via RTSP and SDK
50 fps (384 × 288)
H.264/MJPEG
15 options: White Hot, Black Hot, Fusion 1, Rainbow, Fusion 2, Ironbow 1, Ironbow 2,
Speia, Color 1, Color 2, Ice Fire, Rain, Red Hot, Green Hot, Dark Blue
IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP,
RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Up to 3 channels
Up to 32 users, 3 levels: Administrator, Operator, User
User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE
802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
HIKMICRO Studio
English
10-30 VDC, Max. 2.3 W
0 °C to 200 °C (32 °F to 392 °F); 95% or less with air cooling and liquid cooling ; -20 °C to 65 °C (-4 °F to 149 °F); 95% or less without air cooling or liquid cooling
IP67
352.5 mm × 170.5 mm × 138 mm (13.88" x 6.71" x 5.43")
Approx. 6520 g (14.37 lb)
-20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Max (± 2 °C, ± 2%)
Hot spot, cold spot in real time
10 User Presets
1 User Presets
7 User Presets
Above/Between/Below
Vanadium Oxide Uncooled Focal Plane Arrays
384 x 288
17 μm
8 μm to 14 μm
≤ 35 mK (@25° C,F# = 1.0)
6.5 mm
Athermalized
2.62 mrad
F1.0
60° × 44.1° (H × V)
0.6 m
2×, 4×
(application example with incoming water at 20 °C (68 °F) temperature):
Ambient Temperature 80 °C (176 °F), Flow Rate above 0.65 L/min ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 1.22 L/min ;
Ambient Temperature 150 °C (302 °F), Flow Rate above 1.76 L/min ;
Ambient Temperature 200 °C (392 °F), Flow Rate above 3.3 L/min ;
(application example with incoming air at 20 °C (68 °F) temperature and with pressure 7 bar):
Ambient Temperature 70 °C (158 °F), Flow Rate above 15.34 m³/h ;
Ambient Temperature 85 °C (185 °F), Flow Rate above 32.54 m³/h ;
Ambient Temperature 100 °C (212 °F), Flow Rate above 37.82 m³/h ;
Ambient Temperature 120 °C (248 °F), Flow Rate above 53.97 m³/h ;
1, alarm input (0-3.3 VDC)
1, alarm output; NC, level quantity
1, RJ45 10 M/100 M self-adaptive Ethernet interface
1, RS-485 interface (ModBus available)
1, CVBS output
Ver más
Ver menos
Clear All
Compare
Compare Products(2/6)
View Detail
Compare
Clear All
Compare
Firmware
HM_Firmware_TD2H67_X_5.5.70_230908.zip
7 nov. 2023
42A63A3444D195D440200BB5E92E6845
HM_Firmware_TD2H37_X_5.5.70_230908.zip
7 nov. 2023
8CE567FB384A6E74248D8BB07EB11684

Hikmicrotech.com nos gustaría utilizar cookies de análisis y otras tecnologías de seguimiento similares ("Cookies") para ayudarnos a mejorar nuestro sitio web. Las cookies recopilan información de una forma que no identifica directamente al usuario. Para obtener más información sobre las cookies que utilizamos, consulte nuestra política de cookies aquí.

Aceptar
Rechazar
Gestionar cookies
Servicio online
Área comercial
Ser partner
Soporte técnico
Dónde comprar
close